Ni-thickener Overflow application


Image caption: from left; Filtrate, Feed, Reject

Read more about our recent R&D activity on #mine Ni-thickener overflow application and discover Sofi's capabilities to extract valuable metal from #wastewater streams.

Drivers: Metal recovery for higher yield and #environmental regulations for discharge.   

Solution: A test was carried out in Sofi’s R&D facility in Espoo, Finland to assess the Sofi Filter’s performance in recovering very fine solid particles from ore concentrate water sample collected from a Nickel mine. Trial test was performed using Sofi SF200 with 1 μm screen. The filtrate and concentrate produced during the test are directed back to the feed tank for minimizing water usage during the process.  

Result: In the lab trials, the Sofi's self-cleaning features maintained a flow rate of 9 m3/m2/hr throughout 30-minute wash cycle. The finding shows that Sofi automated plug and play SF200 unit was able to remove 82.2% of solids.  

Flow rate    9 m3/m2/hr   
Filtrate    19 mg/l   
Feed    107 mg/l   
Reject    521 mg/l   

Interested in learning more? Contact at sales@sofiflltration.com